Product
Who We Are

Instant power supply, zero waiting! Perkins original parts starter 2873A030-24-hour global delivery engine parts sales center

Perkins Genuine Starter Motor 2873A030 Exact Fitment – Precision-engineered for 1100/1104 series engines Heavy-Duty Engagement – Withstands 15,000+ cold starts in extreme conditions 3X Longer Lifespan – Carbon brush & copper commutator upgrade reduces wear Global Compliance FAST SHIPPING  📧 Contact: allen@perkins-rx.com (Attach engine model & VIN for priority support)
Product Details
In the operation of power equipment, the starter motor plays a crucial role, and Perkins 2873A030 starter motor is one of the outstanding ones. With its excellent performance, wide applicability, and reliable quality, it has become an ideal choice for many devices.
1、 Product performance highlights
Strong power output: The Perkins 2873A030 starter motor can instantly output powerful torque, easily driving the engine crankshaft to quickly reach the required starting speed. Whether in cold winter or facing high compression ratio engines, it can provide stable and strong initial power to ensure smooth equipment start-up. Its efficient power transmission system can convert electrical energy into mechanical energy in a short period of time, providing strong support for engine start-up.
High reliability design: The starting motor is made of high-quality materials, and the internal key components are treated with special processes, providing excellent wear resistance and fatigue resistance. For example, its electric brush is made of a composite material of high-purity copper and graphite, which not only has good conductivity but also has a long service life, effectively reducing starting failures caused by brush wear. In addition, the windings of the motor are made of high temperature resistant and high-strength insulation materials, which can operate stably in complex working environments and reduce the risk of starting failure caused by electrical faults.
Precise control and stability: Equipped with advanced electromagnetic control mechanism, it can accurately control the on/off and magnitude of the current at the moment of starting, ensuring that the driving gear and engine flywheel mesh quickly and smoothly, avoiding gear damage caused by excessive impact. At the same time, during the start-up process, the output torque can be automatically adjusted according to the actual load situation of the engine, maintaining the stability of the start-up process and improving the success rate and reliability of equipment start-up.
Good low-temperature starting performance: Perkins 2873A030 starter motor has been optimized to address the difficulty of starting equipment in low-temperature environments. The motor adopts a special low-temperature performance enameled wire, which has small resistance changes in low-temperature environments and can ensure the normal operation of the motor. In addition, the electromagnetic switch and control circuit have also been improved for low-temperature adaptability, and can quickly respond to start-up instructions in cold weather, easily achieving low-temperature start-up of the equipment.
📧 Contact: allen@perkins-rx.com

2、 Application Fields
Diesel generator set: As the starting core component of a diesel generator set, the Perkins 2873A030 starter motor can quickly start the generator set in the event of a power outage, providing emergency power support for places such as hospitals, schools, data centers, and communication base stations that require extremely high power continuity. In these places, a power outage may cause serious consequences, and the high reliability and fast starting ability of the starter motor ensure that the generator set can be put into operation in a timely manner to maintain power supply.
Construction machinery: widely used in construction machinery such as excavators, loaders, bulldozers, etc. These devices require frequent start-up at the construction site and work in harsh environments, with strict requirements for the performance and reliability of the starting motor. Perkins 2873A030 starter motor, with its strong power and excellent durability, can work stably in complex working conditions, ensuring efficient operation of construction machinery and improving construction efficiency.
Agricultural machinery: Tractors, combine harvesters, and other agricultural machinery often use this type of starting motor. In agricultural production, the timeliness and stability of equipment start-up directly affect the progress of agricultural operations. This starter motor can work normally in harsh environments such as bumps and dust in farmland, providing support for reliable starting of agricultural machinery and assisting in smooth agricultural production.
  Maintain small knowledge
Regular cleaning: Keep the exterior of the starter motor clean to prevent dust, dirt, and other impurities from entering the interior. Clean the surface of the motor, especially the brush and commutator parts, regularly with a clean cloth or compressed air to prevent impurities from accumulating and affecting the contact performance, leading to poor starting.
Check the wear of the electric brush: Regularly check the degree of wear of the electric brush. When the wear of the electric brush exceeds one-third of its original height, it should be replaced in a timely manner. Excessive wear of the electric brush can lead to an increase in contact resistance, affecting current transmission and reducing the performance of the starter motor. At the same time, when replacing the electric brush, it is necessary to choose a product that matches the prototype number to ensure good conductivity and compatibility.
Maintain the electromagnetic switch: The electromagnetic switch is an important control component of the starter motor, and its wiring should be checked regularly to ensure that it is secure and the contacts are not corroded. If the contact is found to be burnt, it can be lightly sanded with fine sandpaper to make the surface smooth and ensure good contact performance. If the electromagnetic switch malfunctions, it should be repaired or replaced in a timely manner to avoid affecting the normal operation of the starting motor.
Attention to startup operation specifications: When starting the device, the startup time should not exceed 5 seconds each time, and the interval between two startups should be greater than 15 seconds. If the startup fails multiple times in a row, the cause of the fault should be investigated to avoid overheating and damage to the starting motor caused by prolonged and frequent startup. In addition, during the start-up process, it should be ensured that the equipment is in neutral or parked state, and it is strictly prohibited to start with load to reduce the workload of the starter motor.
Send Inquiry
Name *
Phone *
Company *
E-mail *
Message Content *